R1000_single

Mid-scale RUO Processing Assemblies

Static electroporation processing assemblies for research applications in mid-volume scales.

Row herosectionWave Shape Decorative svg added to top
Row seperator3 Shape Decorative svg added to bottom

Research Use Only (RUO) Processing Assemblies enable the discovery and development of applications at mid-scale. These static electroporation consumables are made from high-grade, inert materials to protect precious cells with additional design features for easy sample loading and recovery.

Choose the right processing assembly for your application

OC-400TM RUO

Mid-scale applications and scale-up optimization, single-well

OC-400 RUOâ„¢

Mid-scale applications and scale-up optimization
For quick single sample transfection
Specifically designed for efficient cell loading and recovery

Configuration: Single well, 400 µL maximum volume
Cell Range: 1x106 – 8x107
Volume Range: 200 - 400 µL
Application: Research Use Only
Catalog: SOC-4

OC-400-v-CL-1@2x

Graph Details: To make a master mix, HEK 293 cells were suspended in MaxCyte® Electroporation Buffer at a density of 1x108 cells/mL with pGFP at 200 µg/mL. 400 µL of the master mix was loaded into the OC-400, 1 mL was loaded into one CL-1.1 and 3.5 mL was loaded into a second CL-1.1. Transfection was performed using the MaxCyte HEK electroporation protocol for all 3 PAs. Cells were plated at 3 different densities post-transfection and were analyzed for expression on a flow cytometer after 48 hours.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

R-1000TM

Mid-scale applications and scale-up optimization, single-well

R-1000â„¢

Mid-scale production applications
Optimization bridge to higher production scales
Efficient and high cell recovery

Configuration: Single-well, 1000 µL maximum volume
Cell Range: 2x106 – 2x108
Volume Range: 400 µL - 1 mL
Application: Research Use Only
Catalog: ER001M1-10

Bauer-R-1000-Efficiency-Data-Graphic@2x

Graph Details: KG1a cells were suspended in MaxCyte Electroporation Buffer and mRNA GFP. Electroporation was performed on the MaxCyte GTx™ instrument using the same protocol for all processing assemblies. Final volumes for R-1000, OC-400 and CL-1.1 were 900 μL, 400 μL and 1 mL, respectively. Nine replicates were performed for the R-1000 and OC-400 and three replicates for the CL-1.1, with averages calculated for all graphs.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

CL-1.1TM RUO

Mid-scale applications and scale-up, closed chamber

CL-1.1â„¢ RUO

Closed chamber with luer locking syringe port
Mid-range production scale
Made from high grade, inert materials to protect precious cells

Configuration: Closed chamber, 3.5 mL maximum volume
Cell Range: 5x106 – 7x108
Volume Range: 1 – 3.5 mL
Application: Research Use Only
Catalog: SCL-1

OC-400-v-CL-1@2x

Graph Details: To make a master mix, HEK 293 cells were suspended in MaxCyte Electroporation Buffer at a density of 1x108 cells/mL with pGFP at 200 µg/mL. 400 µL of the master mix was loaded into the OC-400, 1 mL was loaded into one CL-1.1 and 3.5 mL was loaded into a second CL-1.1. Transfection was performed using the MaxCyte HEK electroporation protocol for all 3 PAs. Cells were plated at 3 different densities post-transfection and were analyzed for fluorescence after 48 hours.

atx@2x (1)

For small to medium scale transfection

stx@2x (1)

For high yield transient expression of complex proteins, vaccines and biologics

Row seperator3 Shape Decorative svg added to top

Related Reagents and Supporting Products

Related products to consider using with the mid-scale series of Processing Assemblies.

Hyclone-Buffer@2x

Buffer MaxCyte Electroporation Buffer that works with all cell types

PX5

Px5 Workflow Rack Static Processing Assembly rack to assist with workflow management

3.5Kx3@2x

3.5Kx3 Loading Rack CL-1.1 Processing Assembly rack to assist with loading and workflow management

bagkit@2x

Closed Buffer MaxCyte Electroporation Buffer that works with all cell types in a closed process adaptable bag

Find More

Need additional information or assistance choosing the right processing assembly?

about-maxcyte@2x